Network > Interfaces
235
SonicOS 5.8.1 Administrator Guide
If you want to enable remote management of the SonicWALL security appliance from this
interface, select the supported management protocol(s): HTTP, HTTPS, SSH, Ping, SNMP,
and/or SSH. You can also select HTTP for management traffic. However, bear in mind that
HTTP traffic is less secure than HTTPS. You can also set the level of security (HTTP or HTTPS)
at this time.
Step 4 Click on the Advanced Tab.
You will see two radio buttons, one for T1 and
one for E1. Only one button should be selected
at a time. Different Line Coding, Framing and Encapsulation configuration choices are offered,
depending on the button.
Step 5 Select the Clock Source: Internal or External. This selection is the same for both T1 and E1.
Step 6 Select the Line Coding option:
• When T1 is selected the choices are: B8ZS, AMI
• When E1 is selected the choices are: HDB3, AMI
Step 7 Select the Framing configuration:
• When T1 is selected the choices are: D4 (SF), ESF
• When E1 is selected the choices are: FAS, MFAS
Step 8 Select the DSO speed: 56 KB or 64KB (default).
If desired, you can specify the Data DSO range.
For T1, the range is 1 to 24 (default)
For E1, the range is 1 to 31
Each number can be individually set. For example, “5 to 15”, “1 to 1”, 1 to 20” are valid settings.