720
Code Domain
View/Display
Base Code Length
Toggle the Walsh base code length between 64 and 128.
The Base Code Length for Power Bar Graph and CDE Graph functions are coupled to each other.
Consolidated Marker
Toggle the consolidated marker function between On and Off.
The Consolidated Marker for Power Bar Graph and CDE Graph functions are coupled to each other.
Remote Command :CALCulate:CDPower:WCODe:ORDer HADMrd|BREVerse
:CALCulate:CDPower:WCODe:ORDer?
Example CALCulate:CDPower:WCODe:ORDer HADMrd
CALCulate:CDPower:WCODe:ORDer?
Dependencies/Couplings This command is effective only when the CDP window is selected.
Preset HADMrd
State Saved Saved in instrument state.
Range Hadamard|Bit Reverse
Key Path
View/Display, Power Graph & Metrics
Mode cdma2000
Remote Command :CALCulate:CDPower:WCODe:BASE <integer>
:CALCulate:CDPower:WCODe:BASE?
Example CALCulate:CDPower:WCODe:BASE 64
CALCulate:CDPower:WCODe:BASE?
Restriction and Notes Set the base code length (64 or 128)
This key is grayed out when MS is selected as Radio device
Dependencies/Couplings This command is effective only when the CDP window is selected.
Preset 64
State Saved Saved in instrument state.
Range 64, 128
Key Path
View/Display, Power Graph & Metrics
Remote Command :DISPlay:CDPower:MARKer:CONSolidated ON|OFF|1|0
:DISPlay:CDPower:MARKer:CONSolidated?
Example DISPlay:CDPower:MARKer:CONSolidated ON
DISPlay:CDPower:MARKer:CONSolidated?