Agilent Technologies U9072A cdma-2000 Blood Glucose Meter User Manual


  Open as PDF
of 1403
 
1249
Source (Internal)
Notes: The parameters are:
(There is a total of 11 items in each step, the following is a list of the items in
the order they must appear in the remote command.)
1. Step Trigger <enum> - specifies the input trigger for the step. For details of
the valid types of step trigger see “Step Trigger” on page 1222.
2. Transition Time <time> - specifies the transition time for the stepin
seconds. For details of the valid ranges for the transition time see “Transition
Time” on page 1224.
3. Radio Band <enum> - specifies the radio band for the step. For details of
the valid radio bands see “Radio Setup” on page 1225.
4. Radio Band Link <enum> - specifies the radio band link direction for the
step. For details of the valid link types, see “Radio Band Link” on page 1240.
5. Frequency/Channel Number <freq>/<chan num> - specifies the frequency
in Hz or the channel number for the step. The channel number and frequency
are combined as one parameter that represents the frequency or channel
number depending on the radio band setting. If the radio band is set to NONE,
this value is interpreted as a frequency value in Hz. If the radio band is set to a
valid band, this value is interpreted as a channel number. For details of the
valid ranges for frequency and channel numbers, see “Channel” on page 1240
and “Frequency” on page 1241 .
6. Power <ampl> - specifies the output power for the step in dBm. For details
of the valid ranges see “Power” on page 1242.
7. Waveform <string> - specifies the waveform for playback during the step.
The step can output either a new ARB waveform, continue playback of the
previous waveform, or output a CW tone. The options for specifying these
are:
<filename> - plays the specified waveform from the start. The filename value
is the name of the file within ARB playback memory, it is does not include the
windows path to the file on the HDD. If you enter a filename for a waveform
that does not reside within ARB playback memory, an error is generated.
CONT – continues playback of the ARB file from the previous step
CW – outputs a CW tone
OFF – disable RF output
8. Step Duration <enum> - specifies the duration of the step. The duration can
be specified to be either time, or play count of the ARB file associated with
the step, or continuous. If Waveform is set to “CW”, this value cannot be set to
Play Count and an error will be generated. If continuous is selected, the
following Time or Count value is ignored. For further details of this setting,
see “Step Duration” on page 1245.
9. Time or Count <time/int> - specifies time duration in seconds or play count
of the ARB file associated with the step. For further details of this setting,
including the valid ranges for the time or play count setting, “Time” on
page 1246 and “Play Count” on page 1246.
10. Output Trigger <Boolean> - specifies the output trigger for the step. For
details of the ranges for this setting see “Output Trigger” on page 1248.