Step Configuration of Power parameter list (Remote Command Only)
This SCPI command is to configure “Power”parameter array of the whole List Sequencer at one time. The number
of array is same as step number defined in “Number of Steps” on page 1221 Number of Steps. As a step is setup,
the value entered run through several levels of validation.
Step Configuration of Waveform parameter list (Remote Command Only)
This SCPI command is to configure “Waveform” parameter array of the whole List Sequencer at one time. The
number of array is same as step number defined in “Number of Steps” on page 1221 Number of Steps. As a step is
Notes: The command is to setup below parameter array of whole list sequence.
Frequency/Channel Number <freq>/<chan num> - specifies the frequency in
Hz or the channel number for the step. The channel number and frequency are
combined as one parameter that represents the frequency or channel number
depending on the radio band setting. If the radio band is set to NONE, this
value is interpreted as a frequency value in Hz. If the radio band is set to a
valid band, this value is interpreted as a channel number. For details of the
valid ranges for frequency and channel numbers, see “Channel” on page 1240
and “Frequency” on page 1241
This SCPI is used to setup/query channel number or frequency setting,
according to current Radio Band setting of that step. If Radio Band is
“NONE”, then it’s frequency. If Radio Band is not “NONE”, then it’s channel
number
If input parameter number exceeds the step number defined by Number of
Steps then generate error ", and only those parametes whose index number
falls in legal step number will be updated.
Dependencies: The range is 1 to 1000 which is determined by the number of steps you have
configured. For details see “Number of Steps” on page 1221.
Initial S/W Revision: A.09.40
Remote Command: :SOURce:LIST:SETup:AMPLitude <ampl>, <ampl>, <ampl>, …
:SOURce:LIST:SETup:AMPLitude?
Example: SOUR:LIST:SET:AMPL –50dBm,–40dBm,–30dBm
SOUR:LIST:SET:AMPL?
Notes: The command is to setup below parameter array of whole list sequence.
Power <ampl> - specifies the output power for the step in dBm. For details of
the valid ranges see “Power” on page 1242.
If input parameter number exceeds the step number defined by Number of
Steps then generate error ", and only those parametes whose index number
falls in legal step number will be updated.
Dependencies: The range is 1 to 1000 which is determined by the number of steps you have
configured. For details see “Number of Steps” on page 1221.
Initial S/W Revision: A.09.40