Agilent Technologies U9072A cdma-2000 Blood Glucose Meter User Manual


  Open as PDF
of 1403
 
478
Spectrum Emission Mask Measurement
All (see details) 5 Meas Type: Power Spectral Density Reference
Returns comma-separated scalar values (in dBm/Hz) of the absolute
integrated power of the segment frequencies. The length of the result depends
on the number of available offset (See “Number of Offsets” on page 486).
Returns –999.0 for the offsets if in WLAN:
1. Power spectral density reference (dBm/Hz)
2. Reserved for the future use, returns –999.0
3. Absolute integrated power at negative offset frequency (A)
4. Absolute integrated power at positive offset frequency (A)
25. Absolute integrated power at negative offset frequency (L)
26. Absolute integrated power at positive offset frequency (L)
In WLAN mode.
Returns 26 comma-separated scalar values (in dBm/Hz) of the absolute
integrated power of the segment frequencies:
1. Ref carrier power (dBm/Hz)
2. Reserved for the future use, returns –999.0
3. Absolute integrated power at negative offset frequency (A)
4. Absolute integrated power at positive offset frequency (A)
25. Absolute integrated power at negative offset frequency (L)
26. Absolute integrated power at positive offset frequency (L)
If the result is not available, –999.0 is returned.
The number of values returned is subject to change in future releases.
All (see details) 5 Meas Type: Spectrum Peak Reference
Returns comma-separated scalar values (in dBm) of the absolute peak power
of the segment frequencies. The length of the result depends on the number of
available offset (See “Number of Offsets” on page 486).
1. Spectrum Peak Power reference (dBm)
2. Reserved for the future use, returns –999.0
3. Absolute peak power at negative offset frequency (A)
4. Absolute peak power at positive offset frequency (A)
25. Absolute peak power at negative offset frequency (L)
26. Absolute peak power at positive offset frequency (L)
Modes n Return Value