4 - 8
4. SYSTEM STARTUP
Control cycle settings are imported during system startup (system command code: 000Ah), and cannot be
changed during system running (system status code: 000Ah).
(1) System parameter
Parameter
No.
Abbreviation Name Function
0001 *SYSOP1 System option 1
00
Control cycle setting
Set the control cycle
0: 0.88ms
1: 0.44ms
2: 0.22ms
SSCNET communication method
Set the SSCNET communication
method.
0: SSCNET /H
(Note) SSCNET communication
method is shared in lines
1 and 2.
0002 *SYSOP2 System option 2
Axis No. assignment
Set 1 when validating axis No.
assignment. When axis No.
assignment is invalid, axis No. is
automatically assigned.
0: Invalid
1: Valid
Consistency check selection at
system startup
Set whether to perform consistency
check for controlled axes setting at
system startup.
0: Valid
1: Invalid
00
(2) System information
Address Name Description
0004h Control cycle status 0001h: 0.88ms
0002h: 0.44ms
0003h: 0.22ms
0005h
0006h Reserved
0007h