6 - 2
6. APPLICATION FUNCTIONS
Example: Relationship between setting range of electronic gear and corresponding maximum revolution speed
Number of encoder pulses per
revolution [pulse]
Electronic gear (CMX/CDV)
Maximum speed (limited)
[r/min]
262144
1/16 135000
1/1 2160000
10/1 4893355
10000/1 4893355
1048576
1/16 33750
1/1 540000
10/1 1223338
10000/1 1223338
4194304
1/16 8437
1/1 135000
10/1 305834
10000/1 305834
16777216
1/16 2109
1/1 33750
10/1 76458
10000/1 76458
67108864
1/16 527
1/1 8437
10/1 19114
10000/1 19114
Note. The smaller the setting value of the electronic gear (CMX/CDV) is, the more the maximum
revolution speed is limited. If the maximum revolution speed is limited and the enough speed
cannot be output, reexamine the command unit of the user program and make sure the setting
value of the electronic gear (CMX/CDV) becomes larger. (The command unit becomes rough.)