7.12.3 Command/status data
The system command/status data related to the sampling function are shown below.
(1) Sampling setting write (command)
Address Name Setting range Remarks
BDA0 Sampling setting
write number
0000h to
00AFh
Set the sampling setting number to be written.
Note. For 0000h, sampling setting number error does not occur.
BDA1
BDA2 Reserved
BDA3
BDA4 Sampling setting
write data
00000000h to
FFFFFFFFh
Set the data of the sampling setting number to be written.
BDA5
BDA6
BDA7
(2) Sampling setting write (status)
Address Name Output limits Remarks
BDA8 Sampling setting
write number
0000h to
FFFFh
Displays the sampling setting number which was written.
BDA9
BDAA Reserved
BDAB
BDAC Sampling setting
write data
00000000h to
FFFFFFFFh
Displays the data of the sampling setting number which was written.
BDAD
BDAE
BDAF
(3) Sampling setting read (command)
Address Name Setting range Remarks
BDB0 Sampling setting
read number
0000h to
00AFh
Set the sampling setting number to be read.
Note. For 0000h, sampling setting number error does not occur.
BDB1
BDB2 Reserved
BDB3
BDB4
BDB5
BDB6
BDB7
(4) Sampling setting read (status)
Address Name Output limits Remarks
BDB8 Sampling setting
read number
0000h to
FFFFh
Displays the sampling setting number which was read.
BDB9
BDBA Reserved
BDBB
BDBC Sampling setting
read data
00000000h to
FFFFFFFFh
Displays the data of the sampling setting number which was read.
BDBD
BDBE
BDBF