7. AUXILIARY FUNCTION
(6) Sampled data read command
Address Name Setting range Remarks
BDE0 Sampling read page
number
0 to 256 Set the page number which is read in the sampling data read area. 12 points
of sampled data are read per page.
Note. When start sampling, set 0.
BDE1
BDE2 Reserved
BDE3
BDE4
BDE5
BDE6
BDE7
(7) Sampled data read status
Address Name Output limits Remarks
BDE8 Read sampled data
completion page
number
2 to 256 The page number which is transferred to the sampling data read area is
stored.
2: Sampling read error
1: Sampling reading
0: When sampling read number is 0
1 to 256: Page number whose sampled data is read
BDE9
BDEA Valid read sampled
points
0 to 16 The number of sampled data in the page where sampling read is completed is
stored.
The user program needs to read the sampling data read area and to refer to
the data of this valid read sampled points. All sampled data after the valid
sampled points is 0.
0 to 16 points: Data points sampled in a page
BDEB
BDEC Sampling completion
page number
0 to 256 The page number where sampling is completed by the position board is
stored.
0: Sampling trigger waiting or the page number 1 (only the first
time) is being sampled
1 to 256: Sampling completion page number
BDED
BDEE Reserved
BDEF