3 - 2
3. INSTALLATION AND WIRING
3.2 Connection and disconnection of cable
3.2.1 SSCNET
cable
(1) Precautions for handling the SSCNET
cable
• Do not stamp the SSCNET
cable.
• When laying the SSCNET
cable, be sure to secure the minimum cable bend radius or more. If the bend
radius is less than the minimum cable bend radius, it may cause malfunctions due to characteristic
deterioration, wire breakage, etc.
• For connection and disconnection of SSCNET
cable, hold surely a tab of cable connector.
1CH
2CH
Position board
(2) Connection of SSCNET
cable
• For connection of SSCNET
cable to the position board, connect it to the SSCNET connector 1CH or
2CH of position board while holding a tab of SSCNET
cable connector. Be sure to insert it until it clicks.
• If the cord tip for the SSCNET
cable is dirty, optical transmission is interrupted and it may cause
malfunctions. If it becomes dirty, wipe with a bonded textile, etc. Do not use solvent such as alcohol.
(3) Disconnection of SSCNET
cable
• For disconnection of SSCNET
cable, pull out it while holding a tab of SSCNET cable connector or the
connector.
• After disconnection of SSCNET
cable, be sure to put a cap (attached to position board or servo
amplifier) to the position board and servo amplifier.
• For SSCNET
cable, attach the tube for protection optical cord's end face on the end of connector.