App. - 74
APPENDIX
App. 6 Cables
In this cable connection diagram, makers of connectors are omitted.
Refer to "App. 7.3 Connector" for makers of connectors.
App. 6.1 SSCNET
cables
Generally use the SSCNET
cables available as our products.
Refer to App. 6.3 for long distance cable up to 100(328.08)[m(ft.)] and ultra-long bending life cable.
(1) Model explanation
Numeral in the column of cable length on the table is a symbol put in the "
" part of cable model. Cables of
which symbol exists are available.
Cable model
Cable length [m(ft.)]
Flex life
Application/
remark
0.15
(
0.49
)
0.3
(
0.98
)
0.5
(
1.64
)
1
(
3.28
)
3
(
9.84
)
5
(
16.40
)
10
(
32.81
)
20
(
65.62
)
30
(
98.43
)
40
(
131.23
)
50
(
164.04
)
MR-J3BUSM 015 03 05 1 3 Standard
Standard cord for
inside panel
MR-J3BUSM-A 5 10 20 Standard
Standard cable for
outside panel
MR-J3BUSM-B
(Note 1)
30 40 50 Long flex
Long distance
cable
Note 1. For the cable of less than 30[m](98.43[ft.]), contact your nearest Mitsubishi sales representative.
(2) Specifications
Description
SSCNET cable model MR-J3BUS M MR-J3BUS M-A MR-J3BUS M-B
SSCNET cable length [m(ft.)]
0.15
(0.49)
0.3 to 3
(0.98 to 9.84)
5 to 20
(16.40 to 65.62)
30 to 50
(98.43 to 164.04)
Optical
cable
(Cord)
Minimum bend radius
[mm(inch)]
25(0.98)
Enforced covering cord: 50 (1.97)
Cord: 25 (0.98)
Enforced covering cord: 50 (1.97)
Cord: 30(1.18)
Tension strength [N] 70 140 420 (Enforced covering cord) 980 (Enforced covering cord)
Temperature range for
use [°C(°F)] (Note 1)
-40 to 80
(-40 to 176)
-20 to 70
(-4 to 158)
Ambient Indoors (no direct sunlight), No solvent or oil
External appearance
[mm(inch)]
(0.09 0.003)
2.2 0.07
10.16(Note 2)
(0.40)
4.4 0.1
(0.17 0.004)
(0.09 0.003)
2.2 0.07
(
0.09 0.003
)
2.2 0.07
4.4 0.1
(0.17 0.004)
6 0.2
(0.24 0.008)
4.4 0.4
(0.17 0.016)
7.6 0.5
(0.30 0.02)
(
0.09 0.008
)
2.2 0.2
Note 1. This temperature range for use is the value for optical cable (cord) only.
Note 2. Dimension of connector fiber insert location. The distance of two cords is changed by how to bend it.