7 - 89
7. AUXILIARY FUNCTION
(2) System Command/Status Data
(a) System Commands
Address Name
Setting
range
Remarks
01B0 Reading of log data
Page number
1 to 256 Sets the page number for the log data area for logged data to be read to.
Data for 16 events of log data are read for each page.
Example. When the number of valid events is 345 events
345/16
21
9
In other words, pages 1 to 22 are read.
01B1
(b) System status
Address Name
Output
limits
Remarks
01F0 Reading of log data
Page number
1 to 256 Stores the page number that was read.
The details for the settings for the page number of the log data that was read
using a system command are stored.
01F1
01F2 Number of valid log data
events
0 to 4096 Stores the number of number of valid events stored in current log data. When
the number of valid events reaches 4096 events the number of valid events
becomes 4096.
01F3