7 - 36
7. AUXILIARY FUNCTION
7.11.4 Disconnection method
SSCNET communication disconnection is executed by turning on the disconnection command after the axis
number of the axis to be disconnected is specified.
The flowchart of the disconnection is shown below.
Turn on the disconnection
command (CCC).
No
Yes
Turn off the disconnection
command (CCC).
END
Set the axis number to be
disconnected to
the disconnection
axis number (Note 1).
No
START
Disconnection
complete (CCF)
ON?
Disconnection
error (CCE)
ON?
Error processing
Yes
Confirm the disconnected
axis from the controlling
axis information.
sscDisconnectSSCNET function
Note 1. Set the axis number by 0000h (axis 1) to 0019h (axis 32).
2. When the consistency check selection at system startup of the control cycle (parameter No.0002) is
valid, disconnection error (CCE) turns on.