6 - 34
6. APPLICATION FUNCTIONS
6.16 Completion of operation signal
The completion of operation signal (OPF) shows a completion of operation status. At the startup, the
"completion of operation signal" (OPF) turns off, and the "completion of operation signal" (OPF) turns on when
positioning operation is complete.
Interruption of operation due to an alarm also turns on the completion of operation signal (OPF).
A summary of operation for each operation mode is shown.
API LIBRARY
Use the sscWaitIntDriveFin/sscGetDriveFinStatus function to check the
completion of operation.
(1) Using a JOG operation
ON
OFF
ON
OFF
ON
OFF
Speed
Start operation (ST)
During operation (OP)
During smoothing of
stopping (SMZ)
ON
OFF
In-position (INP)
ON
OFF
Completion of
operation (OPF)
Start of operation Stop operation
(2) Using incremental feed
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Operation is stopped after
the movement amount
designated by the incremental
feed movement amount is moved.
Speed
Start operation (ST)
During operation (OP)
During smoothing of
stopping (SMZ)
In-position (INP)
Completion of
operation (OPF)
Start of operation