App. - 23
APPENDIX
(2) Operation from the position board
Positioning operation using the position board is basically the same as operation for using a rotary servo
motor.
However, some parameters, home position return operation, command/status bit, and monitor No. vary
from when using a rotary servo motor. Details are as follows.
(a) Parameters
When using the direct drive system, set the parameters shown on the table below.
For other servo parameters, control parameters, and system parameters, set them as equivalent to
using a rotary servo motor.
1) Servo parameters
For details on each parameter, refer to the Servo Amplifier Instruction Manual for your servo amplifier.
<MR-J4(W
)- B>
Parameter
No.
MR-J4-B
Parameter
No.
(Note)
Abbreviation
Name
1100 PA01 **STY Operation mode
1180 PC01 ERZ Error excessive alarm level
1182 PC03 *ENRS Encoder output pulse selection
1300 PL01 **LIT1 Linear servo motor/DD motor function selection 1
1303 PL04 *LIT2 Linear servo motor/DD motor function selection 2
1304 PL05 LB1 Position deviation error detection level
1305 PL06 LB2 Speed deviation error detection level
1306 PL07 LB3 Torque/thrust deviation error detection level
1307 PL08 *LIT3 Linear servo motor/DD motor function selection 3
1308 PL09 LPWM Magnetic pole detection voltage level
1310 PL17 LTSTS
Magnetic pole detection - Minute position detection method -
Function selection
1311 PL18 IDLV
Magnetic pole detection - Minute position detection method -
Identification signal amplitude
Note. Parameters with asterisk (*) before abbreviation will be valid under the following conditions.
*: After setting, turn off the power supply and then on again, or reset controller.
**: After setting, turn off the power supply and then on again.
2) Control parameters
Parameter
No.
(Note1)
Abbreviation
Name
Initial
value
Unit
Setting
range
Function
020A *CMXL Electronic gear
numerator (lower)
0001h 1 to
5242879
(32 bit)
(Note2)
Set the numerator of the electronic gear.
(For setting methods, refer to App. 3.4(2)(c).)
020B *CMXH Electronic gear
numerator (upper)
0000h
020C *CDVL Electronic gear
denominator (lower)
0001h 1 to
589823
(32 bit)
(Note2)
Set the denominator of the electronic gear.
(For setting methods, refer to App. 3.4(2)(c).)
020D *CDVH Electronic gear
denominator (upper)
0000h
021D *VEND Vendor ID 0000h 0000h to
FFFFh
Set the vendor ID.
0000h: Mitsubishi Electric
021E *CODE Type code 1000h 0000h to
FFFFh
Set the type code.
1000h: MR-J4(W
)- B servo amplifier
Note1. Settings for parameters with asterisk (*) before abbreviation will be valid at system startup.
2. The setting range differs depending on the setting of speed units (parameter No.0200). Refer to Section 6.1.1.