App. - 34
APPENDIX
Control cycle settings are imported during system startup (system command code: 000Ah), and cannot be
changed during system running (system command code: 000Ah).
(a) System parameters
Parameter
No.
Abbreviation Name Function
0001 *SYSOP1 System option 1
00
SSCNET communication method
Set the SSCNET communication
method.
0: SSCNET /H (Not use)
1: SSCNET
Make sure to set "1: SSCNET ".
(Note) SSCNET communication
method is shared in lines
1 and 2.
Control cycle setting
Set the control cycle
[When SSCNET communication
method is 1: SSCNET ]
0: 0.88ms
1: 0.44ms
0002 *SYSOP2 System option 2
0
Axis No. assignment
Set 1 when validating axis No.
assignment.
When axis No. assignment is invalid,
axis No is automatically assigned.
0: Invalid
1: Valid
0
Consistency check selection at
system startup
Set whether to perform consistency
check for controlled axes setting at
system startup.
0: Valid
1: Invalid
(b) SSCNET communication method
Address Name Description
0008
SSCNET communication method
1: SSCNET
2: SSCNET
/H
0009