5 - 28
5. OPERATIONAL FUNCTIONS
(3) When the proximity dog is in the opposite direction against the direction of home position return
Home position return direction
Limit switch
Start operation
Amount of home
position shift
Creep speed
Home position
Home position return speed
Z-phase pulse
Speed
Proximity
dog
(4) If a limit switch is detected at the start operation position
If a limit switch in the direction of home position return is detected, the home position return should be
executed by the (3) pattern. Also, if the limit switch is in the opposite direction against the direction of home
position return, the home position return should be executed by the (1) pattern.
(5) When the start operation position is on a dog and when moving in the opposite direction the Z-phase was
not traveled through until the dog is turned off
If the Z-phase is never passed at the end of the
proximity dog, continue movement in the
opposite direction until the Z-phase is passed.
Proximity dog
Home position
Home position return direction
Creep speed
Home position return speed
Home position
return speed
Start
operation
Z-phase pulse
Speed