1 - 23
1. SUMMARY
1.7 Forced stop input terminal
(1) Table of the forced stop input terminal specifications
Item Specifications
Number of input points Forced stop signal: 1 point
Input method Positive common/Negative common shared type
Rated input current 2.4mA
Isolation method Photocoupler
Operating voltage range
20.4 to 26.4VDC
(+10/ -15%, ripple ratio 5% or less)
ON voltage/current 17.5VDC or more/2.0mA or more
OFF voltage/current 1.8VDC or less/0.18mA or less
Input resistance Approx. 10k
Response time
OFF to ON
1ms or less
ON to OFF
External connector type 3 pin connector
Recommended wire size
0.08 to 0.32mm
2
(AWG22 to AWG28)
(2) Forced stop circuit
(a) Positive common
+24V
24G
EMI.COM
EMI
Forced stop input connector
Forced stop
Control
circuit
Position board side
10k
Stabilizing power supply
(b) Negative common
EMI.COM
EMI
Forced stop input connector
Forced stop
Control
circuit
Position board side
10k
+24V
24G
Stabilizing power supply