7 - 107
7. AUXILIARY FUNCTION
7.17.5 Alarm history initialization procedure
The procedure for initialization of parameters are as follows.
Yes
sscClearAlarmHistoryData function
End
No
Note. Set
E15A to the alarm history initialization ID.
Turn off alarm history
initialization command (ALHR)
Alarm history initialization ID
setting
Turn on alarm history
initialization command (ALH)
Start
Alarm
history initialization
complete?
POINT
Do not turn off the power supply to the position board during initialization of
alarm history.
Alarm history data cannot be read during initialization of alarm history.
API LIBRARY
Use the sscClearAlarmHistoryData function to initialize alarm history.
7.17.6 List of system errors that do not apply to alarm history storage
System errors that do not apply to alarm history storage are shown below.
Error code Content
E001 ROM error
E002 RAM error 1
E003 Dual port memory error
E004 RAM error 2
E006 SSCNET communication IC error 1
E007 SSCNET communication IC error 2
E008 Board error
E1 CPU error
EF01 System command code error