App. - 32
APPENDIX
App. 5.6 Axis No. setting
Axis No. is set by the axis selection rotary switch (Note). The axis No. and rotary switch No. are correlated as
shown on the table below. Set the axis No. of the servo amplifier so that it will not duplicate in the same
SSCNET line. If it is duplicated, the "An axis that has not been mounted exists" (system error E400) will occur
at the time of system startup (system command code: 000Ah).
Note. The name and setting method of the axis selection rotary switch vary depending on the unit device to
be used. For details, refer to the unit device specification for your unit.
App. 5.6.1 Servo amplifier setting
(1) MR-J3(W)-
B
Axis No. of MR-J3(W)-
B is set by the axis selection rotary switch (SW1) on the servo amplifier. Servo
amplifier axis No. and rotary switch setting are correlated as shown on the table below. Set the axis No. of
the servo amplifier so that it will not duplicate in the same line. If it is duplicated, the "An axis that has not
been mounted exists" (system error E400) will occur at the time of system startup (system command code:
000Ah).
Servo
amplifier
axis No.
Axis selection rotary
switch
Servo amplifier display
(3-digit, 7-segment indicator)
d1 0 01
d2 1 02
d3 2 03
d4 3 04
d5 4 05
d6 5 06
d7 6 07
d8 7 08
d9 8 09
d10 9 10
d11 A 11
d12 B 12
d13 C 13
d14 D 14
d15 E 15
d16 F 16
POINT
For each switch setting, refer to the Servo Amplifier Instruction Manual for
your servo amplifier.
If the "An axis that has not been mounted exists" (system error E400)
occurred, the axis with wrong axis No. set can be confirmed with "information
concerning axis that is not mounted" (monitor No.0480 to 0482).
The servo amplifier axis No. and the axis No. to be managed on the position
board are different. For details, refer to App. 5.9.