6 - 4
6. APPLICATION FUNCTIONS
6.1.4 Restrictions
The restrictions on electronic gears are shown below.
(1) When the setting of an electronic gear (CMX, CDV, CMX/CDV) is incorrect, an electronic gear setting error
(system error E500) occurs at system startup and the electronic gear setting is treated as CMX: CDV = 1: 1.
The operation cannot be performed since the electronic gear is in forced stop status at this time.
Reexamine the setting of an electronic gear and start the system again.
(2) When an electronic gear setting error occurs while using the absolute position detection system, the
absolute position erased signal (ABSE) and the home position return request (ZREQ) turn on. For the
absolute position detection system, refer to Absolute position detection system (Section 6.21).
(3) When an electronic gear setting error occurs, the axis with wrong electronic gear set can be confirmed with
"electronic gear setting error axis information" (monitor No.0488 to 0489).