Mitsubishi Electronics MR-MC210 Sleep Apnea Machine User Manual


 
3 - 5
3. INSTALLATION AND WIRING
POINT
• Migratable plasticizer is used for vinyl tape. Keep the MR-J3BUS M, and
MR-J3BUS
M-A cables away from vinyl tape because the optical
characteristic may be affected.
Optical cord
Cable
SSCNET cable Cord Cable
MR-J3BUS M
MR-J3BUS M-A
MR-J3BUS M-B
: Normally, cable is not affected by plasticizer.
: Phthalate ester plasticizer such as DBP and DOP may affect optical
characteristic of cable.
Generally, soft polyvinyl chloride (PVC), polyethylene resin (PE) and fluorine
resin contain non-migratable plasticizer and they do not affect the optical
characteristic of SSCNET
cable. However, some wire sheaths and cable
ties, which contain migratable plasticizer (phthalate ester), may affect
MR-J3BUS
M and MR-J3BUS M-A cables (made of plastic). In addition,
MR-J3BUS
M-B cable (made of quartz glass) is not affected by plasticizer.
• If the adhesion of solvent and oil to the cord part of SSCNET
cable may
lower the optical characteristic and machine characteristic. If it is used such
an environment, be sure to do the protection measures to the cord part.
• When keeping the position board or servo amplifier, be sure to put on a cap
to connector part so that a dirt should not adhere to the end of SSCNET
connector.
• SSCNET
connector to connect the SSCNET cable is put a cap to protect
light device inside connector from dust. For this reason, do not remove a cap
until just before connecting SSCNET
cable. Then, when removing
SSCNET
cable, make sure to put a cap.
• Keep the cap and the tube for protecting light cord end of SSCNET
cable
in a plastic bag with a zipper of SSCNET
cable to prevent them from
becoming dirty.
• When exchanging the position board or servo amplifier, make sure to put a
cap on SSCNET
connector. When asking repair of position board or servo
amplifier for some troubles, make also sure to put a cap on SSCNET
connector. When the connector is not put a cap, the light device may be
damaged at the transit. In this case, exchange and repair of light device is
required.