AT&T 555-230-520 Medical Alarms User Manual


 
stop
Issue 4 September 1995
A-77
Stop Command
stop
Purpose
Halts the processing of any subsequent vector steps.
Syntax
stop
Requirements
Basic Call Vectoring or Call Prompting software must be installed.
Operation
After the
stop
command is processed, any calls already queued remain queued,
and any wait treatment (for example, silence, ringback, music) is continued. On
the other hand, any calls not queued are dropped under the same scenario.
If a TTR is allocated to the call, and if the
stop
command is encountered, the TTR
is disconnected. However, current call processing continues (that is, the call is
not dropped). The caller continues to hear the feedback that was provided
before the
stop
command was encountered.
NOTE:
An implicit stop is processed following the last administered command in a
vector.
Answer Supervision Considerations
The command has no effect on answer supervision.
Feature Interactions
For Look-Ahead Interflow, the command is considered a neutral vector command
in all cases except when a call is dropped, then it is considered a denial.