Emerson Process Management 2400S Pacemaker User Manual


 
64 Micro Motion
®
Model 2400S Transmitters for PROFIBUS-DP
Optional Configuration
A021 Unrecognized/Unentered Sensor Type Fault No No
Incorrect Sensor Type (K1)
A029 Internal Communication Failure Fault No No
PIC/Daughterboard Communication Failure
A030 Hardware/Software Incompatible Fault No No
Incorrect Board Type
A031 Undefined Fault No No
Low Power
A032
(2)
Meter Verification Fault Alarm Fault No No
Meter Verification/Outputs In Fault
A032
(3)
Outputs Fixed during Meter Verification Varies
(4)
No No
Meter Verification In Progress and Outputs
Fixed
A033 Sensor OK, Tubes Stopped by Process Fault Yes Yes
Sensor OK, Tubes Stopped by Process
A034
(3)
Meter Verification Failed Info Yes No
Meter Verification Failed
A035
(3)
Meter Verification Aborted Info Yes No
Meter Verification Aborted
A102 Drive Over-Range/Partially Full Tube Info Yes No
Drive Overrange/Partially Full Tube
A104 Calibration-In-Progress Info Yes
(5)
No
Calibration in Progress
A105 Slug Flow Info Yes No
Slug Flow
A107 Power Reset Occurred Info Yes No
Power Reset Occurred
A116 API Temperature Out-of-Limits Info Yes No
API: Temperature Outside Standard Range
A117 API Density Out-of-Limits Info Yes No
API: Density Outside Standard Range
A120 ED: Unable to fit curve data Info No No
ED: Unable to Fit Curve Data
Table 8-8 Status alarms and severity levels continued
Alarm code Message
(1)
Default
severity Configurable
Affected by
fault timeout