Emerson Process Management 2400S Pacemaker User Manual


 
Configuration and Use Manual 185
PROFIBUS Bus Parameters
Menus Display CodesBus ParametersDiagrams
D.10 I&M functions (Slot 0)
D.11 Totalizer and inventory measurement unit codes
Table D-9 I&M functions
Index
Sub-
index Name Description
Data
type Size
Memory
class Access
255 65000 HEADER Manufacturer- specific STRING 10 S R
MANUFACTURER_
ID
ID for manufacturer that is
assigned by PTO
USINT16 2 S R
ORDER_ID Order number of device STRING 20 S R
SERIAL_NO Production serial number of
device
STRING 16 S R
HARDWARE_
REVISION
Revision number of the
hardware
USINT16 2 S R
SOFTWARE_
REVISION
Software or firmware revision
of device or module
1×CHAR
3×USINT8
4S R
REV_COUNTER Marks the change of hardware
revision or any of its
parameters
USINT16 2 S R
PROFILE_ID Profile type of supporting
profile
USINT16 2 S R
PROFILE_
SPECIFIC_TYPE
Specific profile type USINT16 2 S R
IM_VERSION Implemented version of I&M
functions
2×USINT8 2 S R
IM_SUPPORTED Indicated availability of I&M
functions
USINT16
(1)
(1) Implemented as bit array.
2S R
65001 HEADER Manufacturer-specific STRING 10 S R
TAG_FUNCTION Device identification tag STRING 32 S R/W
TAG_LOCATION Device location identification
tag
STRING 22 S R/W
Table D-10 Mass totalizer and mass inventory measurement unit codes
Code Label Description
1089 g Gram
1088 Kg Kilogram
1092 metric tons Metric ton
1094 lbs Pound
1095 short tons Short ton (2000 pounds)