Emerson Process Management 2400S Pacemaker User Manual


 
184 Micro Motion
®
Model 2400S Transmitters for PROFIBUS-DP
PROFIBUS Bus Parameters
47 SNS_ED_ResetFlag USINT16 S W Reset all density curve data:
• 0x0000 = No action
• 0x0001 = Reset
48 SNS_ED_EnableDens
LowExtrap
USINT16 S R/W Low-density extrapolation alarm:
• 0x0000 = Disable
• 0x0001 = Enable
49 SNS_ED_EnableDens
HighExtrap
USINT16 S R/W High-density extrapolation alarm:
• 0x0000 = Disable
• 0x0001 = Enable
50 SNS_ED_EnableTemp
LowExtrap
USINT16 S R/W Low-temperature extrapolation alarm:
• 0x0000 = Disable
• 0x0001 = Enable
51 SNS_ED_EnableTemp
HighExtrap
USINT16 S R/W High-temperature extrapolation alarm:
• 0x0000 = Disable
• 0x0001 = Enable
52 SNS_ED_LongCurve
Name
OCTET
STRING
S R/W Extended name of curve
Table D-8 Enhanced Density block (Slot 7) continued
Index Name
Data
type
Memory