Configuration and Use Manual 187
PROFIBUS Bus Parameters
Menus Display CodesBus ParametersDiagrams
D.13 Alarm index codes
23 Enhanced density: Standard volume flow rate
24 Enhanced density: Standard volume total
25 Enhanced density: Standard volume inventory
26 Enhanced density: Net mass flow rate
27 Enhanced density: Net mass total
28 Enhanced density: Net mass inventory
29 Enhanced density: Net volume flow rate
30 Enhanced density: Net volume total
31 Enhanced density: Net volume inventory
32 Enhanced density: Concentration
33 API: CTL
46 Tube frequency
47 Drive gain
48 Case temperature
49 Left pickoff amplitude
50 Right pickoff amplitude
51 Board temperature
53 External pressure
55 External temperature
63 Gas standard volume flow rate
64 Gas standard volume total
65 Gas standard volume inventory
69 Live zero
251 None
Table D-14 Alarm index codes
Code Description
1 Nonvolatile memory failure
2 RAM/ROM error
3 Sensor failure
4 Temperature overrange
5 Input overrange
6
Transmitter not characterized
7
Reserved
8
Density overrange
9
Transmitter initializing/warming up
10
Calibration failure
11
Zero too low
Table D-13 Process variable codes continued
Code Description