Emerson Process Management 2400S Pacemaker User Manual


 
178 Micro Motion
®
Model 2400S Transmitters for PROFIBUS-DP
PROFIBUS Bus Parameters
D.6 Device Information block (Slot 4)
Table D-5 Device Information block (Slot 4)
Index Name
Data
type
Memory
class Access Definition/Code/Comments
4 SYS_FeatureKey B_ENUM S R Transmitter options enabled
• 0x0000 = Standard
• 0x0800 = Meter verification
• 0x0008 = Enhanced density
• 0x0010 = Petroleum measurement
5 SYS_CEQ_Number USINT16 S R ETO (Engineering To Order) on transmitter
6 SNS_SensorSerialNum USINT32 S R/W
7 SNS_SensorType STRING S R/W
8 SNS_SensorTypeCode USINT16 S R/W 0 = Curved tube
• 1 = Straight tube
9 SNS_SensorMaterial USINT16 S R/W 0 = None
• 3 = Hastelloy C-22
• 4 = Monel
• 5 = Tantalum
•6 = Titanium
• 19 = 316L stainless steel
• 23 = Inconel
• 252 = Unknown
• 253 = Special
10 SNS_LinerMaterial USINT16 S R/W 0 = None
• 10 = PTFE (Teflon)
• 11 = Halar
• 16 = Tefzel
• 251 = None
• 252 = Unknown
• 253 = Special
11 SNS_FlangeType USINT16 S R/W 0 = ANSI 150
• 1 = ANSI 300
• 2 = ANSI 600
•5 = PN 40
• 7 = JIS 10K
• 8 = JIS 20K
• 9 = ANSI 900
• 10 = Sanitary clamp fitting
• 11 = Union
• 12 = PN 100
• 252 = Unknown
• 253 = Special
12 SNS_MassFlowHiLim FLOAT S R High mass flow limit of sensor
13 SNS_TempFlowHiLim FLOAT S R High temperature limit of sensor
14 SNS_DensityHiLim FLOAT S R High density limit of sensor
15 SNS_VolumeFlowHiLim FLOAT S R High volume flow limit of sensor
16 SNS_MassFlowLoLim FLOAT S R Low mass flow limit of sensor
17 SNS_TempFlowLoLim FLOAT S R Low temperature limit of sensor
18 SNS_DensityLoLim FLOAT S R Low density limit of sensor
19 SNS_VolumeFlowLoLim FLOAT S R Low volume flow limit of sensor
20 SNS_MassFlowLoSpan FLOAT S R Mass flow minimum range of sensor
21 SNS_TempFlowLoSpan FLOAT S R Temperature minimum range of sensor
22 SNS_DensityLoSpan FLOAT S R Density minimum range of sensor