Emerson Process Management 2400S Pacemaker User Manual


 
Configuration and Use Manual 101
Measurement Performance
Measurement Performance DefaultsTroubleshootingCompensation
Figure 10-9 Smart Meter Verification test – PROFIBUS bus parameters
Table 10-4 PROFIBUS bus parameters test interface for Smart Meter Verification
Step number Step description Interface
(1)
1 Set output state Diagnostic block (Slot 3)
• To Fault or Last Measured Value Index 54
• To Continue Measurement Index 53
Step 2
Start/abort procedure
Step 1
Set output state (optional)
Able to
complete?
Step 8
Check abort code
CAUTION
Yes (>0)
Step 3
Check current algorithm state
Running?
Step 4
Read percent complete
Yes (=16)
Step 6
Check inlet stiffness
Within limits? No (>0)
Yes (=0)
Step 7
Check outlet stiffness
Within limits? No (>0)
Yes (=0)
CAUTION
PASS
No (<16)
No (=0)
Manual abort (optional)
Step 5
Check algorithm abort state
See Table 10-4.