Reliant PB6001401 Thermometer User Manual


 
Procedures
12-49
Octel Overture 200/300 Serenade 3.0
PB60014–01
To
log on to the Octel Overture 200/300.
Use the @
DSKTST
<shelf/slot> to initialize slot information on the
destination drive. For example, @
DSKTST
B3. The VCU tests the slot
and updates its status record.
Use the WPDISK /D <slot> command to disable write protect on the
source drive.
The following menu is presented:
@disko
CURRENT STATUS
Slot Type ID Status
––––––––––––––––––––––––––––
B3 System1 S1 ACTIVE Configured
B4 System2 –– EMPTY Not Cfgd
C1 Voice1 –– EMPTY Not Cfgd
C2 Voice2 –– EMPTY Not Cfgd
C3 Voice3 –– EMPTY Not Cfgd
C4 Voice4 –– EMPTY Not Cfgd
DISK OPTIONS
1. ADD DISK
2. REMOVE DISK
3. REPLACE A DISK
4. RESTORE SYSTEM
5. UPGRADE LANGUAGES
6. UPGRADE SYSTEM
7. DISK COPY
Select option to be performed
(1–7 – Empty line = EXIT)
:7
The
Octel Overture 200/300 displays the following screen. (There may be
a delay before the screen appears.)
6.
Adjust the baud rate of the
terminal/teleprinter to 300,
1200, or 9600 baud.
7.
Press the Reload button to boot
from floppy disk.
8.
Insert diskette #2 when
prompted.
9. Press
Enter
10.
Initialize slot information on
destination drive.
11.
Disable write protect on the
source drive.
Choose
the Correct Disk
Option
12. @DISKO
Enter
13. Choose
option 7 —
COPY
DISK