Log
Commands — Log, List Trace, Call Detail Record 7-19
Octel Overture 200/300 Serenade 3.0
PB60014–01
Example
of LAN Channel Number
In
this example, the start time (
S
) is specified as
97 4 21,
and the type of filter (
PR
, for port) is
specified as
101
. This example displays all log entries for activities on LAN channel 1, and it shows
message number 10B3 sent to number F68.
@LOG PR CPT
Specify Print Option(s):
”S”tart <time>, ”E”nd <time>, ”L”ine <length>, ”P”age <length> ”\”
”C”ontinuous
Filters: PR TY EV AU MB MS SL UN LI SO D1 D2 D3 D4 D5
>s 97 4 21 pr 101
MM/DD/YY HH:MM:SS PRT TYPE EVENT AUX MBX/EXTN MSG# SL U L SOURCE
D1 D2 D3 D4 D5
04/21/97 07:23:27 L01 LAN_OUT CONNGRANT 1001
04/21/97 07:23:27 L01 LAN_IN VCUCONN
04/21/97 07:23:27 L01 LAN_OUT STATUS VCUREADY
04/21/97 07:23:27 L01 LAN_OUT STATUS VCUCONN
04/21/97 07:23:27 L01 LAN_IN STRTSND
04/21/97 07:23:27 L01 LAN_IN DESTMBX 110
04/21/97 07:23:27 L01 LAN_OUT STRTSND SUCCESS
04/21/97 07:23:27 L01 LAN_OUT DESTMBX SUCCESS 110
04/21/97 07:23:27 L01 LAN_IN MSGDLV NO_EXTN 10B3 151
04/21/97 07:23:27 L01 LAN_MSG CREATE F68
04/21/97 07:23:28 L01 LAN_OUT STATUS SUCCESS
04/21/97 07:23:28 L01 LAN_OUT STATUS COMPLETE
04/21/97 07:23:28 L01 LAN_MSG RCV SUCCESS F68
04/21/97 07:23:29 L01 LAN_IN CLOSEDONE
LOG for Protocol 5 (OctelNet)
You
can also use the
LOG
command for tracing various events for Protocol 5 (OctelNet) networking. The
applicable events are provided in Appendix A at the end of this chapter
.
The following example uses the
LOG PR CPT
command for OctelNet information. The start time (
S
) is
specified as
97 02 09,
and the type of filter (
TY
) is specified as
ONT
. This example displays all log
entries that start with
ONT
in the
TYPE
column.