Reliant PB6001401 Thermometer User Manual


 
Log
Commands — Log, List Trace, Call Detail Record 7-15
Octel Overture 200/300 Serenade 3.0
PB60014–01
Location Activity
To
print the network location activity
, enter the filter
TY NET_MSG.
Message Activity
To
print message activity that is currently in the CPT log using the
LOG
command, at the @ prompt type
LOG PR CPT
Enter
To
list all messages or specify a specific message number
, type the filter
MS.
@LOG PR CPT
Specify Print Option(s):
“S”tart <time>, “E”nd <time>, “L”ine <length>, “p”age <length> “\”
”C”ontinuous
Filters: PR TY EV AU MB MS SL UN LI SO D1 D2 D3 D4 D5
>MS 3000
In
this example, this command displays all records for message 3000, from the beginning of the log until
the end.
Integration Activity
To
display integration activity using
LOG,
specify the type of integration to trace; enter the filter
TY X,
where
X
is the type of integration to trace. Enter
TY INTG
to show all integration activity:
- INTG_C
. Card-based integration record (MIC, RIC, A
TTIC, SL1, M1)
- INTG_CA
. Card-based ANI integration record (MIC, RIC, A
TTIC, SL1, M1)
- INTG_R
. RS-232C integration record
- INTG_D
. DTMF integration record
In addition to
TY
, the following filters can also be specified for integration:
- SL
. Slot number for card integration
- UN
. Unit number for card integration
- LI
. Link number for card integration
- SO
. Source of call (integration)
T
o display APlink activity using
LOG
, at the @ prompt type
@LOG PR CPT
Specify Print Option(s):
“S”tart <time>, “E”nd <time>, “L”ine <length>, “p”age <length> “\”
”C”ontinuous
Filters: PR TY EV AU MB MS SL UN LI SO D1 D2 D3 D4 D5
>TY AP S 97 7 9 11 25