Reliant PB6001401 Thermometer User Manual


 
System
Errors and T
raf
fic Pegs 8-25
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
15 = NO SELF IP ADDRESS CONFIGURED
17 = SNMP SYSTEM MANAGER NOT KNOWN, TRAP MUST BE SENT
18 = NO AP ERROR MAILBOX (SYSTEM PARAMETER 145).
42. Configuration
Error
(continued)
Error detected in the
configuration tables
Check the configuration tables.
1
19 = SELF MUST BE CONFIGURED
SOURCE:
Unable
to build network creator
s address for delivery of
a network message.
REMEDY:
Add a numbering plan entry for SELF in the
NUMBERING PLAN Table.
1A = OCTELNET SYSTEM MAILBOX NOT CONFIGURED
SOURCE:
The
OctelNet System mailbox (System Parameter 248)
has not been configured.
REMEDY:
Configure the OctelNet System mailbox. Refer to the
Configuration
volume, Remote Analog Networking
chapter
, Configuration, System Parameters, and COS
Attributes sections.
1B = OCTELNET SYSTEM MAILBOX DOES NOT HAVE COS ATTRIBUTE
82
SOURCE:
The
OctelNet System mailbox does not have Class of
Service Attribute 82.
REMEDY:
Add COS Attribute 82 —
THIS USER MAY RECEIVE FAX
MESSAGES
,
to the COS of the OctelNet System mailbox.
T
o add COS Attribute 82 requires that a suf
ficient number
of Fax Mail Plus licenses are authorized.
1C = OCTELNET MAXIMUM FAX TRANSMISSION TIME IS SET TO
ZERO
SOURCE:
The
OctelNet maximum fax transmission time (System
Parameter 252) is set to zero.
REMEDY:
Set System Parameter 252 —
OCTELNET: MAX FAX
TRANSMIT TIME
,
to at least 1 minute.