Reliant PB6001401 Thermometer User Manual


 
System
Errors and T
raf
fic Pegs 8-35
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
68 BIC
Err
or
Dependent on value in
DATA-1.
Replace CPU card.
DATA-1 = 01 BIC read error (chip bad or missing).
DATA-1 = 02 BIC checksum error
2
DATA-2 = Computed checksum.
DATA-3 = Checksum stored in BIC.
1
69 VCU
port-controller
status
Error
detected with
VCU port controller
.
Contact your technical support center
. 3
DATA-1 = VCU logical port with error status.
DATA-2 = Currently active port-control-block for port-block 0 or 1.
DATA-3 = Port block status.
Bit 0 = Parity error
Bit 1 = Direction error
Bit 2 = Request timing error
Bit 3 = Port operation complete
70 Control
Bus err
or
on a DSP-based
card
Error in Contrl Bus
I/O between CPU and
card.
Replace the DSP-based card. If error
repeats, call your technical support center
.
3
DATA-1 = 01 Timeout on a request from CPU.
02 Timeout on a PIC request.
DATA-2 = Message Type waiting for ___________.
DATA-3 = User Number, if applicable.
71 High
Speed Link
Monitor Err
or
The Digital
Networking
high-speed link is
down more than the
maximum configured
in System Parameters
267–269. An error is
logged per location.
Check remote location to see if digital
networking is up. Follow troubleshooting
guidelines in the
Networking
volume,
Digital Networking chapter
.
3
Data-1
Location number for which logged
Data-2
Sub-type, the possible values are as follows:
1 = continuous downtime exceeded system parameter 267
2 = cumulative downtime exceeded system parameter 268
3 = Number of times down exceeded system parameter 269
Data-3 Unused
Data-4 Unused