Hardware
Replacement 9-25
Octel Overture 200/300 Serenade 3.0
PB60014–01
Installing Fax Application Processors
Use
the following procedure to install a fax card:
1.
Put on an antistatic wrist strap. Connect it to an unpainted portion of the cabinet.
2.
While holding the top and bottom edges of the fax card, slide it into the card cage, taking care to
align the card on the card guides and not let the daughter cards touch nearby cards.
3.
Pivot the card ejectors, as needed, to grip the small flanges on the front edges of the card cage.
4.
Firmly seat the fax card connectors into the motherboard by pressing the ejectors against the front
edge of the fax card. The ejectors will clip onto the small pins on the fax card when the connectors
are seated.
Caution!
Do not slam the fax card into the cabinet, as this
could damage the card or motherboard connectors.
Once the fax card is installed, the red LED comes ON. When the self-test diagnostics are complete,
the green LED comes ON. When the card has been initialized and is ready for operation, the red
LED goes OFF
.
5.
Use the Courtesy Up command to put the card into service. At the @ prompt, type
CU x
Enter
In this command,
x
is the slot number of the fax card.
6. T
est the fax card for correct operation. Refer to the
Featur
e Description
volume, Fax Mail Plus
chapter, T
esting the Fax Application Processor section, for testing procedures.
7.
Close and lock the door to the cabinet.
Hard-Disk-Drive
Replacement
Hard-disk
drives are already installed in the message server cabinet when it is shipped. When a
replacement is required, certain procedures must be followed to restore a message server to normal
operation.
Hot plug replacement of hard-disk drives is supported. Drives inserted hot are not operational until the
Disk Options (
DISKO
) program is run. There is no online Disk Options program. However
, the command
to add, remove, or replace hard-disk drives must still be issued using the Disk Options program when the
message server is booted from a floppy diskette.
. Y
ou must restart the message server if the hard-disk drive has been replaced.
Refer to the Procedures chapter in this volume, Hard-Disk Replace and Hard-Disk Add sections.
Only
hard-disk drives supplied by Octel can be used to replace or to upgrade a message server
. The disk
drive assembly includes
all necessary
cables.
Do not r
emove or alter any cables on the drive
assembly.
Figure 9-16 shows the hard-disk-drive assembly for the Octel Overture 200. Figure 9-17 shows
the hard-disk-drive assembly for the Octel Overture 300.