Reliant PB6001401 Thermometer User Manual


 
9-30
Installation and Maintenance
V
olume
Octel Overture 200/300 Serenade 3.0
PB60014–01
6. Using
a flat-bladed screwdriver
, tighten the two captive screws that are attached to the front flange of
the drive assembly
.
7.
Connect the keyed connector on the floppy-drive signal cable to the connector on the CPU card.
8.
Insert the configuration backup diskette into the floppy-disk drive.
9. T
est the message server for correct operation.
Power Supply Unit Replacement
If
the power supply unit malfunctions, it must be replaced with a new one. No attempt should be made to
replace or alter the power supply’
s circuit components or wire harness. No power supply adjustments are
possible.
-
For the Octel Overture 200, the power supply and floppy-disk drive are part of the power supply unit.
If either the power supply or floppy-disk drive malfunctions, you must replace the entire unit. The
instructions used to remove and install the power supply are the same instructions used to replace an
Octel Overture 200 floppy-disk drive. Figure 9-19 shows the power supply unit for an Octel Overture
200.
Power Supply
Power Switch
Fuse Holder
Cable to
FloppyĆDisk Drive
FloppyĆDisk Drive
Figure 9-19
Octel Overture 200 Power Supply Unit
- For
the Octel Overture 300, the power supply unit and the floppy-disk drive can be replaced
separately
. Refer to the Octel Overture 300 Floppy-Disk-Drive Replacement section to remove an
Octel Overture 300 floppy-disk drive. Figure 9-20 shows the power supply assembly for the Octel
Overture 300.