Reliant PB6001401 Thermometer User Manual


 
4-52
Installation and Maintenance
Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
When
all Octel Overture 200/300 port extensions pass these tests, proceed by connecting the 25-pair
cables to the Octel Overture 200/300 and test the message server for standard operation. The Octel
Overtur
e 200/300
must initialize each of the PBX ports.
T
o verify that all the ports ar
e
initialized, at the
@
pr
ompt, type
PS.
All ports should return
IDL.
Test
for Call to a Ring-No-Answer Extension
. The
extension to be called must have a valid first digit (a mailbox with this first digit must already
exist in the USER T
able) or be entered in the USER T
able as a mailbox (mailbox number same as
the extension number and a COS).
V
erify that the Octel Overture 200/300
correctly handles a ring-no-answer (RNA) call.
1.
From telephone A, call the extension associated with port 1.
2.
Did the Octel Overture 200/300 answer with the correct company greeting (a custom greeting or the
generic greeting)?
YES ' Continue.
NO '
Determine the cause and correct the problem before continuing.
3.
Enter the extension number for telephone C.
4.
Did the Octel Overture 200/300 respond with the prompt:
“Thank you, just a
moment .
. .” (Primary
Answer Mode example)?
YES ' Continue.
NO
'
Determine the cause and correct the problem before continuing.
5.
After a predetermined interval (defined by the entry in the INFORMA
TION T
able for ringbacks
before no answer), does the message server reconnect and speak the prompt
“Extension XXX doesn’
t
answer
. Please leave a message at the tone, or enter another extension number
, or pr
ess zer
o for
assistance”?
.
If the mailbox has not been entered in the USER T
able, the Octel Overture 200/300 does not
of
fer to take a message.
YES '
Press
9
9
, then hang up.
NO '
Determine the cause and correct the problem before continuing.
6.
Repeat the test for each Octel Overture 200/300 port.
Test
for Calls to a Busy Extension
Verify
that the Octel Overture 200/300
properly handles a call directed to a busy extension.
1.
From telephone A, call the extension associated with port 1.
2.
Did the Octel Overture 200/300 answer with the correct company greeting?
YES ' Continue.
NO
'
Determine the cause and correct the problem before continuing.