4-56
Installation and Maintenance
Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
13. Repeat
the procedure from step 3 for all ports, until all ports are busied out. V
erify that calls can be
placed through the Octel Overture 200/300 from each port.
14.
From telephone A, call out and back in on a trunk dedicated to the hunt group.
15.
Does the call overflow to the correct destination?
YES ' Continue.
NO '
Determine the cause and correct the problem before continuing.
.
Some PBXs might not support overflow
, in which case a ring-no-answer condition could be
encountered.
16.
Remove the busy condition from all Octel Overture 200/300 port extensions.
17.
Repeat steps 3 through 13 except call an extension that does not answer
, and then repeat it by calling
a busy extension.
Test
to Verify T
runks
1. From
telephone A, call outside the PBX and back in on the first trunk dedicated to the Octel
Overture 200/300.
2.
Does the Octel Overture 200/300 answer correctly?
YES ' Continue.
NO
'
Determine the cause and correct the problem before continuing.
3.
Repeat the procedure from step 1 for each trunk, until all hunts have been tested. V
erify that each
trunk is answered by the Octel Overture 200/300 with the correct greeting.
. T
oll-free service lines can be tested individually
, even if they are bands from other areas, by
using the “plant test” number
. Get these from the PE (Public Exchange) if you do not know
them.
Test for Calls to the Intercept Extension
Verify
that the Octel Overture 200/300 can transfer a call to the intercept position (attendant) when the
caller does nothing or presses
0
, as follows:
1.
From telephone A, call the extension associated with port 1.
2.
Does the Octel Overture 200/300 answer correctly?
YES ' Continue.
NO '
Determine the cause and correct the problem before continuing.
3.
Listen to the complete company greeting. Do nothing, let the Octel Overture 200/300 time out, and
transfer the call to the attendant (do not enter any digits).
4.
Did you reach the attendant?
YES '
Continue for all ports.
NO '
Determine the cause and correct the problem before continuing.
5.
Repeat the procedure except press
0
instead of waiting for a timeout.