2. INSTALLATION
(b) Installation of two or more servo amplifiers
POINT
Close mounting is available for the servo amplifier of under 3.5kW for 200V
class and 400W for 100V class.
Leave a large clearance between the top of the servo amplifier and the internal surface of the control
box, and install a cooling fan to prevent the internal temperature of the control box from exceeding the
environmental conditions.
When installing the servo amplifiers closely, leave a clearance of 1mm between the adjacent servo
amplifiers in consideration of mounting tolerances.
In this case, bring the ambient temperature within 0 to 45
(32 to 113 ), or use it at 75% or smaller
effective load ratio.
40mm or more
Control box
30mm
or more
30mm
or more
Control box
Leaving clearance
Mounting closely
30mm
or more
1mm 1mm
100mm
or more
30mm
or more
100mm
or more
10mm
or more
40mm
or more
Top
Bottom
(2) 11k to 22kW
(a) Installation of one servo amplifier
40mm or more
10mm
or more
120mm
or more
Wiring allowance
80mm
Top
Bottom
Servo amplifier
Control box Control box
10mm
or more