The following are setting values for regenerative resistor and regenerative option which are used with a
servo amplifier of 11k to 22kW.
Regenerative resistor, regenerative option
Setting
value
Standard supplied regenerative resistor 00
Standard supplied regenerative resistor
(with a cooling fan to cool it)
FA
MR-RB5E 00
MR-RB5E (with a cooling fan to cool it) FA
MR-RB9P 00
MR-RB9P (with a cooling fan to cool it) FA
MR-RB9F 00
MR-RB9F (with a cooling fan to cool it) FA
MR-RB6B-4 00
MR-RB6B-4 (with a cooling fan to cool it) 00
MR-RB60-4 FA
MR-RB60-4 (with a cooling fan to cool it) 00
MR-RB6K-4 FA
MR-RB6K-4 (with a cooling fan to cool it) 00
(4) Connection of the regenerative option
POINT
When the MR-RB50 MR-RB51 MR-RB3M-4 MR-RB3G-4 MR-RB5G-4
MR-RB34-4
MR-RB54-4 is used, a cooling fan is required to cool it.
The cooling fan should be prepared by the customer.
For the sizes of wires used for wiring, refer to section 11.11.
The regenerative option will cause a temperature rise of
100 relative to the ambient temperature. Fully
examine heat dissipation, installation position, used cables, etc. before installing the option. For wiring, use
flame-resistant wires and keep them clear of the regenerative option body. Always use twisted cables of
max. 5m length for connection with the servo amplifier.