5 - 21
5. PARAMETERS
No. Symbol Name and function
Initial
value
Unit
Setting
range
PC12 MO2 Analog monitor 2 offset
Used to set the offset voltage of the analog monitor 2 (MO2) output.
0 mV -999
to
999
PC13 MOSDL Analog monitor feedback position output standard data Low
Used to set the standard position of feedback output with analog monitor 1 (M01) or 2
(M02).
For this parameter, the lower-order four digits of standard position in decimal numbers
are set.
0 pulse -9999
to
9999
PC14 MOSDH Analog monitor feedback position output standard data High
Used to set the standard position of feedback output with analog monitor 1 (M01) or 2
(M02).
For this parameter, the higher-order four digits of standard position in decimal numbers
are set.
0 10000
pulse
-9999
to
9999
PC15 0
PC16
For manufacturer setting
Do not change this value by any means.
0000h
PC17 **COP4 Function Selection C-4
Home position setting condition in the absolute position detection system can be
selected.
Selection of home position setting condition
0: Need to pass motor Z-phase after the power
supply is switched on.
1: Not need to pass motor Z-phase after the power
supply is switched on.
000
0000h Refer to
Name
and
function
column.
PC18 0000h
PC19 0000h
PC20
For manufacturer setting
Do not change this value by any means.
0000h
PC21 *BPS Alarm history clear
Used to clear the alarm history.
Alarm history clear
0: Invalid
1: Valid
When alarm history clear is made valid, the alarm
history is cleared at next power-on.
After the alarm history is cleared, the setting is
automatically made invalid (reset to 0).
000
0000h Refer to
Name
and
function
column.
PC22 0000h
PC23
For manufacturer setting
Do not change this value by any means.
0000h
PC24 0000h
PC25 0000h
PC26 0000h
PC27 0000h
PC28 0000h
PC29 0000h
PC30 0000h
PC31 0000h
PC32
0000h