(b) When using the 600V Grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Selection example of wire size when using HIV wires is indicated below. For the wire (8)) for power
regeneration converter (FR-RC-(H)), use the IV wire indicated in (1) (a) in this section.
Table 11.2 Wire size selection example 2 (HIV wire)
Wires [mm
2
] (Note 1, 4)
Servo amplifier
1)
L
1 L2 L3
2) L11 L21
3)
U
V W
4) P C 5) B1 B2
6)
BU
BV BW
7)
OHS1 OHS2
MR-J3-10B(1)
MR-J3-20B(1)
MR-J3-40B(1) 1.25(AWG16)
MR-J3-60B 2(AWG14)
MR-J3-70B
1.25(AWG16)
2(AWG14)
MR-J3-100B 1.25(AWG16)
MR-J3-200B 2(AWG14)
MR-J3-350B 3.5(AWG12) 3.5(AWG12)
MR-J3-500B
(Note 2)
5.5(AWG10): a 5.5(AWG10): a 2(AWG14): g
MR-J3-700B
(Note 2)
8(AWG8): b
1.25(AWG16):
h
8(AWG8): b 2(AWG14): g
1.25(AWG16)
(Note 3)
1.25(AWG16)
(Note 3)
MR-J3-11KB
(Note 2)
14(AWG6): c 14(AWG6): c
MR-J3-15KB
(Note 2)
22(AWG4): d
1.25(AWG16):
g
22(AWG4): d
3.5(AWG12): j 1.25(AWG16)
1.25(AWG16) 1.25(AWG16)
MR-J3-22KB
(Note 2)
38(AWG1): p 38(AWG1): p 5.5(AWG10): k
MR-J3-60B4
MR-J3-100B4 2(AWG14) 1.25(AWG16)
1.25(AWG16)
2(AWG14)
MR-J3-200B4 2(AWG14)
MR-J3-350B4 2(AWG14): g 2(AWG14): g
MR-J3-500B4
(Note 2)
3.5(AWG12): a
MR-J3-700B4
(Note 2)
3.5(AWG12): a
1.25(AWG16):
h
5.5(AWG10): a
2(AWG14): g
1.25(AWG16)
(Note 3)
1.25(AWG16)
(Note 3)
MR-J3-11KB4
(Note 2)
5.5(AWG10): j 8(AWG8): l 2(AWG14): q
MR-J3-15KB4
(Note 2)
8(AWG8): l
1.25(AWG16):
g
14(AWG6): c 3.5(AWG12): j 1.25(AWG16) 1.25(AWG16)
MR-J3-22KB4
(Note 2)
14(AWG6): m 14(AWG6): m 3.5(AWG12): k
Note 1. Alphabets in the table indicate crimping tools. For crimping terminals and applicable tools, refer to (1) (c) in this section.
2. When connecting to the terminal block, be sure to use the screws which are provided with the terminal block.
3. For the servo motor with a cooling fan.
4. Wires are selected based on the highest rated current among combining servo motors.