1. FUNCTIONS AND CONFIGURATION
(2) MR-J3-60B4
MR-J3-100B4
(Note 3)
Power supply
R S T
No-fuse breaker
(NFB) or fuse
Magnetic
contactor
(MC)
(Note 2)
Line noise
filter
(FR-BSF01)
L
2
L
3
(Note 2)
Power factor
improving DC
reactor
(FR-BEL-H)
P
1
P2
Regenerative option
PC
L
11
L
21
UVW
(Note 1)
Battery
MR-J3BAT
CN5
CN3
CN1A
CN1B
CN2
CN4
MR Configurator
Personal
computer
Junction
terminal
block
Servo system
controller or Front axis
servo amplifier CN1B
Rear servo amplifier
CN1A or Cap
Servo motor
Servo amplifier
L
1
Note 1. The battery (option) is used for the absolute position detection system in the position control mode.
2. The AC reactor can also be used. In this case, the DC reactor cannot be used. When not using DC reactor, short P
1 and P2.
3. A 1-phase 200V to 230VAC power supply may be used with the servo amplifier of MR-J3-70B or less.
For 1-phase 200V to 230VAC, connect the power supply to L
1 L2 and leave L3 open. Refer to section 1.3 for the power supply
specification.