Emerson Process Management Model 2700 Pacemaker User Manual


 
Configuration and Use Manual 57
Configuration
Startup ConfigurationCalibrationBefore You Begin Startup ConfigurationCalibrationBefore You Begin Startup ConfigurationCalibrationBefore You Begin Startup ConfigurationCalibrationBefore You Begin
4.6.2 Configuration procedure
The petroleum measurement configuration parameters are listed and defined in Table 4-9.
Setting the table type
To set the petroleum measurement table type, refer to the flowcharts in Figure 4-4.
Table 4-8 Petroleum measurement reference temperature tables
Table
CTL
derivation
method Base temperature
Density unit and range
Degrees API Base density Relative density
5A Method 1 60 °F, non-configurable 0 to +100
5B Method 1 60 °F, non-configurable 0 to +85
5D Method 1 60 °F, non-configurable –10 to +40
23A Method 1 60 °F, non-configurable 0.6110 to 1.0760
23B Method 1 60 °F, non-configurable 0.6535 to 1.0760
23D Method 1 60 °F, non-configurable 0.8520 to 1.1640
53A Method 1 15 °C, configurable 610 to 1075 kg/m
3
53B Method 1 15 °C, configurable 653 to 1075 kg/m
3
53D Method 1 15 °C, configurable 825 to 1164 kg/m
3
Reference temperature Supports
6C Method 2 60 °F, non-configurable 60 °F Degrees API
24C Method 2 60 °F, non-configurable 60 °F Relative density
54C Method 2 15 °C, configurable 15 °C Base density in kg/m
3
Table 4-9 Petroleum measurement parameters
Variable Description
Table type Specifies the table that will be used for reference temperature and reference density unit. Select
the table that matches your requirements. See Petroleum measurement reference tables.
User defined TEC
(1)
(1) Configurable if Table Type is set to 6C, 24C, or 54C.
Thermal expansion coefficient. Enter the value to be used in CTL calculation.
Temperature units
(2)
(2) In most cases, the temperature unit used by the petroleum measurement reference table should also be the temperature unit configured
for the transmitter to use in general processing. To configure the temperature unit, see Section 4.5.
Read-only. Displays the unit used for reference temperature in the reference table.
Density units Read-only. Displays the unit used for reference density in the reference table.
Reference
temperature
Read-only unless Table Type is set to 53x or 54x. If configurable:
• Specify the reference temperature to be used in CTL calculation.
• Enter reference temperature in °C.