Emerson Process Management Model 2700 Pacemaker User Manual


 
Configuration and Use Manual 161
Model 2700 PROFIBUS Block Parameters
Status Bytes Block ParametersDiagnostic BytesProLink
143 PA_StatusWords5
(DD Name: Alarm Five Status)
Status Word 5 ENUM BIT_ENUM
ERATED
2 D/20 - R 0x0001 = Boot sector
(CP)
0x0002 = Not Used
0x0004 = Not Used
0x0008 = Not Used
0x0010 = Not Used
0x0020 = Not Used
0x0040 = D3 in
progress
0x0080 = D4 in
progress
0x0100 = Not Used
0x0200 = Not Used
0x0400 = Temp slope
in progress
0x0800 = Temp offset
in progress
0x1000 = FD in
progress 0x2000 =
D2 in progress
0x4000 = D1 in
progress
0x8000 = Zero in
progress
R-423
144 PA_StatusWords6
(DD Name: Alarm Six Status)
Status Word 6 ENUM BIT_ENUM
ERATED
2 D/20 - R 0x0001 = Not Used
0x0002 = Not Used
0x0004 = Not Used
0x0008 = Not Used
0x0010 = Not Used
0x0020 = Not Used
0x0040 = Not Used
0x0080 = Not Used
0x0100 = DE0 active
0x0200 = DE1 active
0x0400 = DE2 active
0x0800 = DE3 active
0x1000 = DE4 active
0x2000 = Not Used
0x4000 = Not Used
0x8000 = Incorrect
Board Type
(A30)
R-424
145 PA_StatusWords7
(DD Name: Alarm Seven
Status)
Status Word 7 ENUM BIT_ENUM
ERATED
2 D/20 --- R 0x0001 = K1/FCF
combination
Unrecognized.
0x0002 = Warming
Up
0x0004 = Low Power
(A31)
0x0008 = Tube Not
Full (A33)
0x0010 = Meter
Verification / Outputs
in fault (A32)
0x0020 = Meter
Verification / Outputs
at last value (A131)
0x0040 = PIC UI
EEPROM Error
0x0080 = Not Used
0x0100 = Not Used
0x0200 = Not Used
0x0400 = Not Used
0x0800 = Not Used
0x1000 = Not Used
0x2000 = Not Used
0x4000 = Not Used
0x8000 = Not Used
R-433
146 PA_StatusWords8
(DD Name: Alarm Eight Status)
Status Word 8 ENUM BIT_ENUM
ERATED
2 D/20 --- R 0x0001 = Not used
0x0002 = Not Used
0x0004 = Not Used
0x0008 = Not Used
0x0010 = Not Used
0x0020 = Not Used
0x0040 = Not Used
0x0080 = Not Used
0x0100 = Not Used
0x0200 = Not Used
0x0400 = Not Used
0x0800 = Not Used
0x1000 = Not Used
0x2000 = Not Used
0x4000 = Not Used
0x8000 = Not Used
R-434
147 SYS_DigCommFaultAction
Code
(DD Name Digital Comm Fault
Action)
Fault Limit Code ENUM Unsigned16 2 S 0 R/W 0 = Upscale
1 = Downscale
2 = Zero
3 = NAN
4 = Flow goes to zero
5 = None
R-124
148 DB_SYS_TimeoutValueLMV
(DD Name : Last Measured
Value Timeout)
Last Measure Value Fault
Timeout
VARIABLE Unsigned16 2 S 0 R/W 0 to 60 R-314
Table F-5 Transducer block 1 parameters (continued)
Index Parameter Mnemonic Definition Message
Ty pe
Data Type/
Structure
Size Store
/Rate
(HZ)
Default
Value
Access Enumerated List of
Values / Range
Modbus
Register /
Coil