Emerson Process Management Model 2700 Pacemaker User Manual


 
Configuration and Use Manual 169
Model 2700 PROFIBUS Block Parameters
Status Bytes Block ParametersDiagnostic BytesProLink
233 UI_ProcessVariables
(LDO_VAR_2_CODE)
(DD Name: Display Variable 2)
Display the Variable#2
associated with the code on the
LDO
ENUM Unsigned16 2 S 2 R/W 0 = Mass Flow Rate
1 = Temperature
2 = Mass Total
3 = Density
4 = Mass Inventory
5 = Volume Flow
Rate
6 = Volume Total
7 = Volume Inventory
8 – 11 = Not used
12= Not used
13= Not used
14= Not used
15 = API: Corr
Density
16 = API: Corr Vol
Flow
17 = API: Corr Vol
Tota l
18 = API: Corr Vol Inv
19 = API: Avg
Density
20 = API: Avg Temp
21 = ED: Density At
Ref
22 = ED: Density (
SGU)
23 = ED: Std Vol
Flow Rate
24 = ED: Std Vol
Tota l
25 = ED: Std Vol
Inventory
26 = ED: Net Mass
Flow
27 = ED: Net Mass
Tota l
28 = ED: Net Mass
Inv
29 = ED: Net Vol
Flow Rate
30 = ED: Net Vol
Tota l
31 = ED: Net Vol
Inventory
32 = ED:
Concentration
33 = API: CTL
34-45 = Not used
46 = Raw Tube
Frequency
47 = Drive Gain
48 = Case
Temperature
49 = LPO Amplitude
50 = RPO Amplitude
51 = Board
Temperature
52 = Input Voltage
53 = Ext. Input
Pressure
54 = Not used
55 = Ext. Input Temp
56 = ED: Density
(Baume)
57 = Not used
58 = Not used
59 = Not used
60 = Not used
61 = Not used
62 = Gas Std Vol
Flow
63 = Gas Std Vol
Tota l
64 = Gat Std Vol
Inventory
65 = Not used
66 = Not used
67 = Not used
68 = Not used
69 = Live Zero
70 – 101 = Not used
102 = Not used
103 = Not used
104 = Not used
105 – 250 = Not used
251 = None
252 – 255 = Not used
R-1118
234 UI_ProcessVariables
(LDO_VAR_3_CODE)
(DD Name: Display Variable 3)
Display the Variable #3
associated with the code on the
LDO
ENUM Unsigned16 2 S 5 R/W Same as
LDO_VAR_2_CODE
R-1119
235 UI_ProcessVariables
(LDO_VAR_4_CODE)
(DD Name: Display Variable 4)
Display the Variable#4
associated with the code on the
LDO
ENUM Unsigned16 2 S 6 R/W Same as
LDO_VAR_2_CODE
R-1120
236 UI_ProcessVariables
(LDO_VAR_5_CODE)
(DD Name: Display Variable 5)
Display the Variable#5
associated with the code on the
LDO
ENUM Unsigned16 2 S 3 R/W Same as
LDO_VAR_2_CODE
R-1121
237 UI_ProcessVariables
(LDO_VAR_6_CODE)
(DD Name: Display Variable 6)
Display the Variable#6
associated with the code on the
LDO
ENUM Unsigned16 2 S 1 R/W Same as
LDO_VAR_2_CODE
R-1122
Table F-5 Transducer block 1 parameters (continued)
Index Parameter Mnemonic Definition Message
Ty pe
Data Type/
Structure
Size Store
/Rate
(HZ)
Default
Value
Access Enumerated List of
Values / Range
Modbus
Register /
Coil