Model 2700 PROFIBUS Block Parameters
Status Bytes Block ParametersDiagnostic BytesProLink
F.4.13 Totalizer block parameters
Table F-18 lists the parameters for the totalizer blocks.
17 ST_REV 2
18 TAG_DESC
19 STRATEGY
20 ALERT_KEY
21 TARGET_MODE
22 MODE_BLK 3
23 ALARM_SUM 8
Overall sum of bytes in View Object 13
OD
Index
Parameter Mnemonic View 1 View 2 View 3 View 4
Standard Parameters
28 READBACK 5
47 POS_D 2
49 CHECK_BACK 3
61 Overall sum of bytes in View Object
(+ 13 Standard parameters bytes)
10+13
Table F-18 Totalizer block parameters
Index Parameter Mnemonic Definition Message
Ty pe
Data Type/
Structure
Size Store
/Rate
(HZ)
Default
Value
Access Enumerated List of
Values / Range
Modbus
Register /
Coil
Standard PA parameters
16 BLOCK_OBJECT This object contains the
characteristics of the block
RECORD DS-32 20 S ---- R NA NA
17 ST_REV A block has static block
parameters that are not
changed by the process.
Values are assigned to this
parameter during the
configuration of optimization.
The value of ST_REV
increases by 1 after every
change of a static block
parameter.
SIMPLE Unsigned16 2 N 0 R NA NA
18 TAG_DESC Every block can be assigned
a textual TAG description.
The TAG_DESC must be
unambiguous and unique in
the field bus system.
SIMPLE OCTET
STRING
32 S ‘ ’ R/W NA NA
19 STRATEGY Grouping of function block.
The STRATEGY field can be
used to group blocks.
SIMPLE Unsigned16 2 S 0 R/W NA NA
20 ALERT_KEY This parameter contains the
identification number of the
plant unit.
SIMPLE Unsigned8 1 S 0 R/W NA NA
21 TARGET_MODE This parameter contains
desired mode normally set by
a control application of an
operator. The modes are
valid alternatively only, i.e.
only one mode can be set at
one time. A write access to
this parameter with more than
one mode is out of the range
of the parameter and has to
be rejected.
SIMPLE Unsigned8 1 S Auto
(0x08)
R/W 0x08 – Auto
0x10 – Manual
0x80 – OOS
R-2287
22 MODE_BLK This parameter contains the
current mode and the
permitted and normal mode
of the block.
RECORD DS-37 3 D --- R NA R-2288
23 ALARM_SUM This parameter contains the
current states of the block
alarms.
RECORD DS-42 8 D 0,0,0,
0
RNA NA
24 BATCH This parameter is intended to
be used in Batch applications
in line with IEC 61512 Part 1.
Only Function Blocks carry
this parameter. There is no
algorithm necessary within a
Function Block.
RECORD DS-67 10 S 0,0,0,
0
RW NA NA
Table F-17 AO function block views