Emerson Process Management Model 2700 Pacemaker User Manual


 
Configuration and Use Manual 41
Calibration
Startup ConfigurationCalibrationBefore You Begin
Figure 3-12 D1 and D2 density calibration – EDD
Figure 3-13 D1 and D2 density calibration – Bus parameters
D2 calibrationD1 calibration
Calibration >
Density Cal
Fill sensor with D1
fluid
Start Lo Density Cal
Low Density Cal in
progress
Execute
Fill sensor with D2
fluid
Start Hi Density Cal
High Density Cal in
progress
Execute
Done
D1 = density of D1
fluid
D2 = density of D2
fluid
D2 CalibrationD1 Calibration
Block: Transducer Block 1 (Slot 11)
Index 87 (low density cal)
Initiate D1 calibration
Fill sensor with D1
fluid
Block: Transducer Block 1 (Slot 11)
Index 92 (K1)
Check K1 value
Block: Transducer Block 1 (Slot 11)
Index 143, Bit 0x4000
Check status
Block: Transducer Block 1 (Slot 11)
Index 141, Bits 0x0100, 0x0200,
and 0x0400
Check for failure
alarms
Block: Transducer Block 1 (Slot 11)
Index 97 (D1)
Enter density of D1
fluid
Block: Transducer Block 1 (Slot 11)
Index 88 (high density cal)
Initiate D2 calibration
Fill sensor with D2
fluid
Block: Transducer Block 1 (Slot 11)
Index 93 (K2)
Check K2 value
Block: Transducer Block 1 (Slot 11)
Index 143, Bit 0x2000
Check status
Block: Transducer Block 1 (Slot 11)
Index 141, Bits 0x0100, 0x0200,
and 0x0400
Check for failure
alarms
Block: Transducer Block 1 (Slot 11)
Index 98 (D2)
Enter density of D2
fluid
Done