Emerson Process Management Model 2700 Pacemaker User Manual


 
Configuration and Use Manual 153
Model 2700 PROFIBUS Block Parameters
Status Bytes Block ParametersDiagnostic BytesProLink
F.3.1 Physical block object
Table F-3 shows the physical block object.
43 COND_STATUS_DIAG Condensed Status Diagnostics Simple Unsigned-8 1 S 0 R/W 0: Status and
Diagnosis is
provided as
defined in
-PROFIBUS
Profile:
“PROFIBUS-PA
Profile for Process
Control Devices”
V3.01,
December 2004.
PNO-Order-No.
3.042.
1: Condensed
Status and
Diagnosis
information is
provided. NA
NA
44 Reserved
45 Reserved
46 Reserved
47 Reserved
48 Reserved
49 Physical Block Views
Table F-3 Physical block object
Slot/Index Element name Data type Size in bytes Value
Slot 0/Index 16 Reserved Unsigned 8 1 250 (default)
Block_Object Unsigned 8 1 01
Parent_Class Unsigned 8 1 01
Class Unsigned 8 1 250 (default)
DD_Refrence Unsigned 32 4 00 ,00, 00, 00 (Reserved)
DD_Revision Unsigned 16 2 00 ,00 (reserved)
Profile Octet String 2 64 02 (compact class B)
Profile_Revision Unsigned 16 2 03 01 (3.01)
Execution_Time Unsigned 8 1 00 (for future use)
Number_Of_Parameters Unsigned 16 2 00 26 ( Max no of Physical Block
Parameters)
Address_of_View_1 Unsigned 16 2 00 49 (slot, index)
Number_of_Views Unsigned 8 1 01 (1 view)
Table F-2 Physical block parameters (continued)
Index Parameter Mnemonic Definition Message
Ty pe
Data Type/
Structure
Size Store
/Rate
(HZ)
Default
Value
Access Enumerated List of
Values / Range
Modbus
Register /
Coil