Emerson Process Management Model 2700 Pacemaker User Manual


 
Configuration and Use Manual 173
Model 2700 PROFIBUS Block Parameters
Status Bytes Block ParametersDiagnostic BytesProLink
15 SNS_FlangeType
(DD Name : Sensor Flange)
Flange Type ENUM Unsigned16 2 S 0 R/W 0 = ANSI 150
1 = ANSI 300
2 = ANSI 600
5 = PN 40
7 = JIS 10K
8 = JIS 20K
9 = ANSI 900
10 = Sanitary Clamp
Fitting
11 = Union
12 = PN 100
252 = Unknown
253 = Special
R-0129
16 SNS_MassFlowLoSpan
(DD Name: Mass Minimum
Span)
Mass flow minimum range VARIABLE FLOAT 4 S Calc R N/A R-181-182
17 SNS_TempFlowLoSpan
(DD Name: Temp Minimum
Span)
Temperature minimum range VARIABLE FLOAT 4 S Calc R N/A R-183-184
18 SNS_DensityLoSpan
(DD Name: Density Minimum
Span)
Density minimum range
(g/cc)
VARIABLE FLOAT 4 S Calc R N/A R-185-186
19 SNS_VolumeFlowLoSpan
(DD Name: Volume Minimum
Span)
Volume flow minimum range VARIABLE FLOAT 4 S Calc R N/A R-187-188
20 SYS_BoardRevision Board Revision VARIABLE Unsigned8 1 S R N/A R-1163
21 SNS_HartDeviceID(0)
(DD Name: Hart Device ID - 0)
Hart device ID. Mapped with
R122 of core
VARIABLE Unsigned32 4 D R N/A R-1187
22 SNS_HartDeviceID(1)
(DD Name: Hart Device ID - 1)
Hart device ID. Mapped with
R122 of core
VARIABLE Unsigned32 4 D R N/A R-1188
23 EMPTY
24 EMPTY
25 EMPTY
26 EMPTY
27 EMPTY
28 EMPTY
Petroleum Measurement
API Process Variables
29 SNS_API_CorrDensity
(DD Name : PMI TC Density)
Temp Corrected Density RECORD 101 5 D ---- R R-0325-326
30 SNS_API_CorrVolFlow
(DD Name : PMI TC Volume
Flow)
Temp Corrected (Standard)
Volume Flow
RECORD 101 5 D ---- R R-0331-332
31 SNS_API_AveCorrDensity
(DD Name : PM Batch
Weighted Average Density)
Batch Weighted Average
Density
RECORD 101 5 D ---- R R-0337-338
32 SNS_API_AveCorrTemp
(DD Name : PM Batch
Weighted Average
Temperature)
Batch Weighted Average
Temperature
RECORD 101 5 D ---- R R-339-340
33 SNS_API_CTL
(DD Name :PM CTL)
CTL RECORD 101 5 D ---- R R-0329-330
34 SNS_API_CorrVolTotal
(DD Name : PM TC Volume
Tota l)
Temp Corrected (Standard)
Volume Total
VARIABLE 101 5 D/20 0 R N/A R-0333-0334
35 SNS_API_CorrVolInv
(DD Name : PM TC Volume
Inventory)
Temp Corrected (Standard)
Volume Inventory
VARIABLE 101 5 D/20 0 R N/A R-0335-336
36 SNS_ResetApiRefVolTotal
(DD Name : Reset PM TC
Volume Total)
Reset API Reference Volume
Tota l
METHOD Unsigned8 1 S - R/W 0x00 = None
0x01 = Reset
Coil-0058
37 SNS_ResetAPIGSVInv
(DD Name: Rest PM Volume
Inventory)
Reset API/GSV Inventory
(“On” = Reset, “Off” = N/A)
Method Unsigned8 1 S 0x00 R/W 0x00 = No Effect
0x01 = Reset
Coil-0194
API Setup Data
38 SNS_APIRefTemp
(DD Name:PM Reference
Temp )
API Reference Temp VARIABLE FLOAT 4 S 15 R/W 0 to 100 R-0319-0320
39 SNS_APITEC
(DD Name: PM Thermal
Expansion Coeff)
API Thermal Expansion
Coeff
VARIABLE FLOAT 4 S 0 R/W >= 0.000485 R-0323-0324
Table F-8 Transducer block 2 parameters (continued)
Index Parameter Mnemonic Definition Message Type Data Type/
Structure
Size Store
/Rate
(HZ)
Default
Value
Acce
ss
Enumerated List of
Values / Range
Modbus
Register / Coil